Modbus I/O Module 12VDC Powered
Click here for full documentation
Download Test Utility Program
 Features 8 Relay outputs (5A, 250VAC contacts) 4 Opto-Isolated Inputs with counters 3 Analog Inputs (10 bit) jumper-selectable for 0-5V or 0-20mA 4 Input Counters RS485 or USB (virtual serial port) Can be used as a USB to RS485 converter Watchdog Timer resets the unit when communication from the network master is lost Connections via Pluggable Screw Terminals 1200-38400 Baud Modbus Slave Device
Specifications Power Supply Vs and COM: KTA-224: 9-16V DC (12V Nominal) ~200mA + External 5V drain KTB-224: 18-32V DC (24V Nominal) ~200mA + External 5V drain Analog Input ANx: 0-5V: ~500kΩ effective resistance with no jumper installed 0-20mA: ~250Ω effective resistance with jumper installed Opto-Isolated Input: 0-30V, ~1kΩ effective resistance Relay Outputs: SPDT relays rated to 5A (resistive). 250VAC / 30VDC 5V Auxiliary Supply 5V: 200mA
|
|
|
|
|
| .......................... |
| .......................... |
| .......................... |
| .......................... |
| .......................... |
| .......................... |
|
|
|
|